Managed Pressure Drilling

MPD 5 1/8” 5K DNV OS-E101 Offshore Buffer manifold package with 16DA Valves & BOP Control Panel and Accumulator rack skid – Availability update

Select an MTC in-stock or Advanced Delivery  Managed Pressure Drilling Package Today

One Available Ex-Stock

Subject to prior sale.

MPD 5 1/8” 5K DNV OS-E101 Offshore Buffer manifold package with 16DA Valves & BOP Control Panel and Accumulator rack skid

MPD 5 1/8” 5000psi DNV OS-E101 Buffer manifold package with 16 DA Valve & BOP Control panel, Accumulator rack and Remote HMI panel

 

Contact us for more details on this package. Please visit the contact us page or use the Blog reply form to request information or pricing.

Managed Pressure Drilling Manifold 5k PSI – Availability Update

Select an MTC in-stock or Advanced Delivery  Managed Pressure Drilling Package Today

Two Available End February

Options of Electric or Hydraulic actuated chokes

Subject to prior sale.

Managed Pressure Drilling Manifold – 5000 PSI WP with integrated back pressure control system

Managed Pressure Drilling Manifold 5k PSI

This is a Stock build Managed Pressure Drilling (MPD) manifold which has been designed and manufactured by MTC to automatically maintain the annulus surface back pressure during balanced or underbalanced drilling operations within a predetermined pressure operating window using a set of two tight shut off capable pneumatically actuated full bore drilling chokes controlled by a PLC based control system to maintain the selected set point pressure and an HMI interface panel for operator input of required settings and for displaying control system input and output parameters.

The manifold hardware package consists of:

A fully integral double block and bleed API 4 1/16” 5000psi WP Gate valve manifold design with independent flow paths to dual pneumatically actuated API 4 1/16” 5000psi 3” ID full bore tight shut off capable drilling chokes and including a full bypass or gut line capability. An integrated air powered hydraulic control panel is included to allow easy and rapid activation of the manifold hydraulic valves. The complete manifold assembly is installed in an offshore DNV 2.7-1 approved skid and crash frame with lifting sling set and fork lift pockets and includes an integrated instrumentation air distribution system, explosion proof lighting and large general purpose toolbox.

The manifold choke control system hardware and software package consists of:

A Zone 1 Eexd enclosure and an intrinsically safe operator control panel enclosure which houses the touch screen HMI panel and set of control options selection switches to control the MPD choke manifold functions. A set of intrinsically safe pressure and temperature transmitters to provide the input to the control system and an intrinsically safe integrated alarm beacon and sounder system all inter-connected via armoured cable and explosion proof Zone 1 glanding.

The choke control system software has been designed to automatically control the Pneumatically actuated drilling chokes either independently or in parallel to accurately maintain a pre-determined upstream set point pressure using a set of very user friendly switching and touch screen interface options to accurately maintain the selected set point pressure during the MPD drilling operations. Listed below are the main Operational and Safety features of the MPD manifold and control system.

  • 100% operational redundancy of the Drilling chokes.
  • Digital and backup mechanical choke position readouts on Drilling chokes.
  • Fail in last position logic in case of power failure on Drilling chokes.
  • Option of flow and density monitoring and recording from standalone Coriolis meter manifold.
  • Includes fixed choke mode for more accurate back-pressure control at higher flow rates.
  • 100% redundancy of the upstream and downstream pressure transmitters.
  • Includes upstream and downstream temperature transmitters.
  • Choke failure and choke plugging logic activates audible and visual alarms.
  • Includes permanent recording of all control system events and input-output data.
  • Double block and bleed API gate valve philosophy on choke and bypass line flow paths.
  • Includes set of integrated 30 meter long SCADA and WITS extension cables to allow remote operation of the manifold control system and additional independent data output to WITS when required.

Managed Pressure Drilling Manifold with Integrated Coriolis Flow Meter 2k PSI – Availability Update

Select an MTC in-stock or Advanced Delivery  Managed Drilling Package Today

One Available Ex-Stock

Subject to prior sale.

Managed Pressure Drilling Manifold with Integrated Coriolis Flow & Density Meter and Back pressure control system – 2000 PSI

Managed Pressure Drilling Manifold with Integrated Coriolis Flow Meter 2k PSI

This is a Stock build Managed Pressure Drilling (MPD) manifold which has been designed and manufactured by MTC to automatically maintain the annulus surface back pressure during balanced or underbalanced drilling operations within a predetermined pressure operating window using a set of two tight shut off capable electrically actuated full bore drilling chokes controlled by a PLC based control system to maintain the selected set point pressure and an HMI interface panel for operator input of required settings and for displaying control system input and output parameters.

The manifold hardware package consists of:

A double block and bleed 4” x 6” ANSI #900 2000psi WP Ball valve design with independent 4” flow paths to dual electrically actuated 3” ID full bore tight shut off capable drilling chokes and including a single block 6” full bore bypass or gut line with an integrated 4” Micro Motion Coriolis Flow and Density meter installed downstream with 4” isolation and 6” bypass ball valves. The complete manifold assembly is installed in an offshore DNV 2.7-1 approved skid and crash frame with lifting sling set and fork lift pockets and includes explosion proof lighting and large general purpose toolbox.

The manifold choke control system hardware and software package consists of:

A set of Zone 1 Eexd enclosures and an intrinsically safe operator control panel enclosure which houses the touch screen HMI panel and set of control options selection switches to control the Managed Pressure Drilling choke manifold functions. A set of intrinsically safe pressure and temperature transmitters to provide the input to the control system and an intrinsically safe integrated alarm beacon and sounder system all inter-connected via armoured cable and explosion proof Zone 1 glanding.

The choke control system software has been designed to automatically control the electrically actuated drilling chokes either independently or in parallel to accurately maintain a pre-determined upstream set point pressure using a set of very user friendly switching and touch screen interface options to accurately maintain the selected set point pressure during the MPD drilling operations. Listed below are the main Operational and Safety features of the Managed Pressure Drilling manifold and control system.

  • 100% operational redundancy of the Drilling chokes.
  • Digital and backup mechanical choke position readouts on Drilling chokes.
  • Fail in last position logic in case of power failure on Drilling chokes.
  • Includes backup mechanical operation of chokes if required.
  • Includes integrated flow and density monitoring and recording.
  • Includes fixed choke mode for more accurate back-pressure control at higher flow rates.
  • 100% redundancy of the upstream and downstream pressure transmitters.
  • Includes upstream and downstream temperature transmitters.
  • Choke failure and choke plugging logic activates audible and visual alarms.
  • Includes permanent recording of all control system events and input-output data.
  • Double block and bleed ANSI / ASME ball valve philosophy on choke flow paths.
  • Includes set of integrated 30 meter long SCADA and WITS extension cables to allow remote operation of the manifold control system and additional independent data output to WITS when required.

Managed Pressure Drilling 2K Coriolis Meter Skid – Availability Update

Select an MTC in-stock or Advanced Delivery  Managed Pressure Drilling Package Today

One Available Ex-Stock

Subject to prior sale.

Managed Pressure Drilling 2K Coriolis Elite 400P Meter Skid with 2700 Transmitter – Click to see data specification

The MTC Coriolis metering manifold has been designed to measure the mass flow or volumetric

flow rate, density and temperature of the drilling return fluids and produced liquids with a

maximum allowable working pressure 2000psi. The flow meter and manifolding come packaged

in a skid and crash frame with fork lift pockets and lifting sling set and can be supplied with DNV

2.7-1 approval if required. Unit is configured for transportation in horizontal position and for

operation in vertical position. The metering skid is equipped with a remote mount transmitter

with local display and two independent 4-20mA outputs for flow rate and density.

Managed Pressure Drilling 2000 PSI Coriolis Meter Skid – Availability Update

Select an MTC in-stock or Advanced Delivery Managed Drilling Package Today

One Available Ex-Stock

Subject to prior sale.

MPD 2K Coriolis Meter Skid – 4″ x 6″ 2000 PSI with Transmitter – Click to see data specification

The MTC Coriolis metering manifold has been designed to measure the mass flow or volumetric

flow rate, density and temperature of the drilling return fluids and produced liquids with a

maximum allowable working pressure 2000psi. The flow meter and manifolding come packaged

in a skid and crash frame with fork lift pockets and lifting sling set and can be supplied with DNV

2.7-1 approval if required. Unit is configured for transportation in horizontal position and for

operation in vertical position. The metering skid is equipped with a remote mount transmitter

with local display and two independent 4-20mA outputs for flow rate and density.

Managed Pressure Drilling Manifold – 5000 PSI WP – Availability Update

Select an MTC in-stock or Advanced Delivery Managed Drilling Package Today

One Available Ex-Stock

Subject to prior sale.

Managed Pressure Drilling Manifold – 5000 PSI WP

Managed Pressure Drilling

This is a Stock build Managed Pressure Drilling (MPD) manifold which has been designed and manufactured by MTC to automatically maintain the annulus surface back pressure during balanced or underbalanced drilling operations within a predetermined pressure operating window using a set of two tight shut off capable pneumatically actuated full bore drilling chokes controlled by a PLC based control system to maintain the selected set point pressure and an HMI interface panel for operator input of required settings and for displaying control system input and output parameters.

The manifold hardware package consists of:

A fully integral double block and bleed API 4 1/16” 5000psi WP Gate valve manifold design with independent flow paths to dual pneumatically actuated API 4 1/16” 5000psi 3” ID full bore tight shut off capable drilling chokes and including a full bypass or gut line capability. An integrated air powered hydraulic control panel is included to allow easy and rapid activation of the manifold hydraulic valves. The complete manifold assembly is installed in an offshore DNV 2.7-1 approved skid and crash frame with lifting sling set and fork lift pockets and includes an integrated instrumentation air distribution system, explosion proof lighting and large general purpose toolbox.

The manifold choke control system hardware and software package consists of:

A Zone 1 Eexd enclosure and an intrinsically safe operator control panel enclosure which houses the touch screen HMI panel and set of control options selection switches to control the MPD choke manifold functions. A set of intrinsically safe pressure and temperature transmitters to provide the input to the control system and an intrinsically safe integrated alarm beacon and sounder system all inter-connected via armoured cable and explosion proof Zone 1 glanding.

The choke control system software has been designed to automatically control the Pneumatically actuated drilling chokes either independently or in parallel to accurately maintain a pre-determined upstream set point pressure using a set of very user friendly switching and touch screen interface options to accurately maintain the selected set point pressure during the MPD drilling operations. Listed below are the main Operational and Safety features of the MPD manifold and control system.

  • 100% operational redundancy of the Drilling chokes.
  • Digital and backup mechanical choke position readouts on Drilling chokes.
  • Fail in last position logic in case of power failure on Drilling chokes.
  • Option of flow and density monitoring and recording from standalone Coriolis meter manifold.
  • Includes fixed choke mode for more accurate back-pressure control at higher flow rates.
  • 100% redundancy of the upstream and downstream pressure transmitters.
  • Includes upstream and downstream temperature transmitters.
  • Choke failure and choke plugging logic activates audible and visual alarms.
  • Includes permanent recording of all control system events and input-output data.
  • Double block and bleed API gate valve philosophy on choke and bypass line flow paths.
  • Includes set of integrated 30 meter long SCADA and WITS extension cables to allow remote operation of the manifold control system and additional independent data output to WITS when required.

Managed Pressure Drilling Manifold 2000 PSI WP – Availability Update

Select an MTC in-stock or Advanced Delivery  Managed Drilling Package Today

One Available Ex-Stock

Subject to prior sale.

Managed Pressure Drilling Manifold with integrated Coriolis Flow & Density Meter – 2000 PSI WP

Managed Pressure Drilling

This is a Stock build Managed Pressure Drilling (MPD) manifold which has been designed and manufactured by MTC to automatically maintain the annulus surface back pressure during balanced or underbalanced drilling operations within a predetermined pressure operating window using a set of two tight shut off capable electrically actuated full bore drilling chokes controlled by a PLC based control system to maintain the selected set point pressure and an HMI interface panel for operator input of required settings and for displaying control system input and output parameters.

The manifold hardware package consists of:

A double block and bleed 4” x 6” ANSI #900 2000psi WP Ball valve design with independent 4” flow paths to dual electrically actuated 3” ID full bore tight shut off capable drilling chokes and including a single block 6” full bore bypass or gut line with an integrated 4” Micro Motion Coriolis Flow and Density meter installed downstream with 4” isolation and 6” bypass ball valves. The complete manifold assembly is installed in an offshore DNV 2.7-1 approved skid and crash frame with lifting sling set and fork lift pockets and includes explosion proof lighting and large general purpose toolbox.

The manifold choke control system hardware and software package consists of:

A set of Zone 1 Eexd enclosures and an intrinsically safe operator control panel enclosure which houses the touch screen HMI panel and set of control options selection switches to control the Managed Pressure Drilling choke manifold functions. A set of intrinsically safe pressure and temperature transmitters to provide the input to the control system and an intrinsically safe integrated alarm beacon and sounder system all inter-connected via armoured cable and explosion proof Zone 1 glanding.

The choke control system software has been designed to automatically control the electrically actuated drilling chokes either independently or in parallel to accurately maintain a pre-determined upstream set point pressure using a set of very user friendly switching and touch screen interface options to accurately maintain the selected set point pressure during the MPD drilling operations. Listed below are the main Operational and Safety features of the Managed Pressure Drilling manifold and control system.

  • 100% operational redundancy of the Drilling chokes.
  • Digital and backup mechanical choke position readouts on Drilling chokes.
  • Fail in last position logic in case of power failure on Drilling chokes.
  • Includes backup mechanical operation of chokes if required.
  • Includes integrated flow and density monitoring and recording.
  • Includes fixed choke mode for more accurate back-pressure control at higher flow rates.
  • 100% redundancy of the upstream and downstream pressure transmitters.
  • Includes upstream and downstream temperature transmitters.
  • Choke failure and choke plugging logic activates audible and visual alarms.
  • Includes permanent recording of all control system events and input-output data.
  • Double block and bleed ANSI / ASME ball valve philosophy on choke flow paths.
  • Includes set of integrated 30 meter long SCADA and WITS extension cables to allow remote operation of the manifold control system and additional independent data output to WITS when required.

Managed Pressure Drilling Manifold 2000 PSI WP

Select an MTC in-stock or Advanced Delivery Managed Drilling Package Today

One Available Ex-Stock

Subject to prior sale.

Managed Pressure Drilling Manifold with integrated Coriolis Flow & Density Meter – 2000 PSI WP

Managed Pressure Drilling Manifold

This is a Stock build Managed Pressure Drilling (MPD) manifold which has been designed and manufactured by MTC to automatically maintain the annulus surface back pressure during balanced or underbalanced drilling operations within a predetermined pressure operating window using a set of two tight shut off capable electrically actuated full bore drilling chokes controlled by a PLC based control system to maintain the selected set point pressure and an HMI interface panel for operator input of required settings and for displaying control system input and output parameters.

The manifold hardware package consists of:

A double block and bleed 4” x 6” ANSI #900 2000psi WP Ball valve design with independent 4” flow paths to dual electrically actuated 3” ID full bore tight shut off capable drilling chokes and including a single block 6” full bore bypass or gut line with an integrated 4” Micro Motion Coriolis Flow and Density meter installed downstream with 4” isolation and 6” bypass ball valves. The complete manifold assembly is installed in an offshore DNV 2.7-1 approved skid and crash frame with lifting sling set and fork lift pockets and includes explosion proof lighting and large general purpose toolbox.

The manifold choke control system hardware and software package consists of:

A set of Zone 1 Eexd enclosures and an intrinsically safe operator control panel enclosure which houses the touch screen HMI panel and set of control options selection switches to control the MPD choke manifold functions. A set of intrinsically safe pressure and temperature transmitters to provide the input to the control system and an intrinsically safe integrated alarm beacon and sounder system all inter-connected via armoured cable and explosion proof Zone 1 glanding.

The choke control system software has been designed to automatically control the electrically actuated drilling chokes either independently or in parallel to accurately maintain a pre-determined upstream set point pressure using a set of very user friendly switching and touch screen interface options to accurately maintain the selected set point pressure during the MPD drilling operations. Listed below are the main Operational and Safety features of the MPD manifold and control system.

  • 100% operational redundancy of the Drilling chokes.
  • Digital and backup mechanical choke position readouts on Drilling chokes.
  • Fail in last position logic in case of power failure on Drilling chokes.
  • Includes backup mechanical operation of chokes if required.
  • Includes integrated flow and density monitoring and recording.
  • Includes fixed choke mode for more accurate back-pressure control at higher flow rates.
  • 100% redundancy of the upstream and downstream pressure transmitters.
  • Includes upstream and downstream temperature transmitters.
  • Choke failure and choke plugging logic activates audible and visual alarms.
  • Includes permanent recording of all control system events and input-output data.
  • Double block and bleed ANSI / ASME ball valve philosophy on choke flow paths.
  • Includes set of integrated 30 meter long SCADA and WITS extension cables to allow remote operation of the manifold control system and additional independent data output to WITS when required.

Managed Pressure Drilling Manifold – 5000 PSI WP

Select an MTC in-stock or Advanced Delivery  Managed Drilling Package Today

One Available End December 2013

Subject to prior sale.

Managed Pressure Drilling  Manifold – 5000 PSI WP

Managed Pressure Drilling Manifold

This is a Stock build Managed Pressure Drilling (MPD) manifold which has been designed and manufactured by MTC to automatically maintain the annulus surface back pressure during balanced or underbalanced drilling operations within a predetermined pressure operating window using a set of two tight shut off capable pneumatically actuated full bore drilling chokes controlled by a PLC based control system to maintain the selected set point pressure and an HMI interface panel for operator input of required settings and for displaying control system input and output parameters.

The manifold hardware package consists of:

A fully integral double block and bleed API 4 1/16” 5000psi WP Gate valve manifold design with independent flow paths to dual pneumatically actuated API 4 1/16” 5000psi 3” ID full bore tight shut off capable drilling chokes and including a full bypass or gut line capability. An integrated air powered hydraulic control panel is included to allow easy and rapid activation of the manifold hydraulic valves. The complete manifold assembly is installed in an offshore DNV 2.7-1 approved skid and crash frame with lifting sling set and fork lift pockets and includes an integrated instrumentation air distribution system, explosion proof lighting and large general purpose toolbox.

The manifold choke control system hardware and software package consists of:

A Zone 1 Eexd enclosure and an intrinsically safe operator control panel enclosure which houses the touch screen HMI panel and set of control options selection switches to control the Managed Pressure Drilling choke manifold functions. A set of intrinsically safe pressure and temperature transmitters to provide the input to the control system and an intrinsically safe integrated alarm beacon and sounder system all inter-connected via armoured cable and explosion proof Zone 1 glanding.

The choke control system software has been designed to automatically control the Pneumatically actuated drilling chokes either independently or in parallel to accurately maintain a pre-determined upstream set point pressure using a set of very user friendly switching and touch screen interface options to accurately maintain the selected set point pressure during the MPD drilling operations. Listed below are the main Operational and Safety features of the Managed Pressure Drilling manifold and control system.

  • 100% operational redundancy of the Drilling chokes.
  • Digital and backup mechanical choke position readouts on Drilling chokes.
  • Fail in last position logic in case of power failure on Drilling chokes.
  • Option of flow and density monitoring and recording from standalone Coriolis meter manifold.
  • Includes fixed choke mode for more accurate back-pressure control at higher flow rates.
  • 100% redundancy of the upstream and downstream pressure transmitters.
  • Includes upstream and downstream temperature transmitters.
  • Choke failure and choke plugging logic activates audible and visual alarms.
  • Includes permanent recording of all control system events and input-output data.
  • Double block and bleed API gate valve philosophy on choke and bypass line flow paths.
  • Includes set of integrated 30 meter long SCADA and WITS extension cables to allow remote operation of the manifold control system and additional independent data output to WITS when required.